DOUT1.STATE AND DOUT2.STATE

Description

Reads the state of one digital output according to the value stated in the command.


  • AKD-C and AKD-N only support DOUT1.

General Information

Type

R/O Parameter

Units

N/A

Range

0 to 1

Default Value

N/A

Data Type

Integer

Start Version

M_01-00-00-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD Profinet Yes
AKD sercos® III Yes
AKD-N Yes
AKD-C Yes

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

Paramter

Fieldbus

Address

Attributes Signed?
DOUT1.STATE

Profinet

2101 Byte No
sercos® III 2 Octets
DOUT2.STATE

Profinet

2106 Byte
sercos® III 2 Octets

Fieldbus

Parameter Instance Data Size Data Type
EtherNet/IP DOUT1.STATE 102 1 Byte Integer
DOUT2.STATE 107

Fieldbus

Index/Subindex

Is 64 bit? Attributes Signed?

Object Start Version

Modbus

202

DOUT1.STATE No 8 bit No

M_01-03-00-000

212 DOUT2.STATE

Related Topics

Digitale Ausgänge